-----BEGIN PRIVACY-ENHANCED MESSAGE-----
Proc-Type: 2001,MIC-CLEAR
Originator-Name: webmaster@www.sec.gov
Originator-Key-Asymmetric:
 MFgwCgYEVQgBAQICAf8DSgAwRwJAW2sNKK9AVtBzYZmr6aGjlWyK3XmZv3dTINen
 TWSM7vrzLADbmYQaionwg5sDW3P6oaM5D3tdezXMm7z1T+B+twIDAQAB
MIC-Info: RSA-MD5,RSA,
 AnlvETqv/h4d8JG7FnwOEO4JeJl0p6W7QV/0zVa0u3R2g5ahiEGU6MtB3ASaIUxM
 JSdzLNeHFYpnoiSA1Qdhmw==

<SEC-DOCUMENT>0000950123-06-000925.txt : 20060131
<SEC-HEADER>0000950123-06-000925.hdr.sgml : 20060131
<ACCEPTANCE-DATETIME>20060131164202
ACCESSION NUMBER:		0000950123-06-000925
CONFORMED SUBMISSION TYPE:	8-K
PUBLIC DOCUMENT COUNT:		3
CONFORMED PERIOD OF REPORT:	20060125
ITEM INFORMATION:		Entry into a Material Definitive Agreement
ITEM INFORMATION:		Departure of Directors or Principal Officers; Election of Directors; Appointment of Principal Officers
ITEM INFORMATION:		Regulation FD Disclosure
ITEM INFORMATION:		Financial Statements and Exhibits
FILED AS OF DATE:		20060131
DATE AS OF CHANGE:		20060131

FILER:

	COMPANY DATA:	
		COMPANY CONFORMED NAME:			ELECTRO OPTICAL SCIENCES INC /NY
		CENTRAL INDEX KEY:			0001051514
		STANDARD INDUSTRIAL CLASSIFICATION:	SURGICAL & MEDICAL INSTRUMENTS & APPARATUS [3841]
		IRS NUMBER:				133986004

	FILING VALUES:
		FORM TYPE:		8-K
		SEC ACT:		1934 Act
		SEC FILE NUMBER:	000-51481
		FILM NUMBER:		06566437

	BUSINESS ADDRESS:	
		STREET 1:		3 WEST MAIN STREET, SUITE 201
		CITY:			IRVINGTON
		STATE:			NY
		ZIP:			10533
		BUSINESS PHONE:		914-591-3783

	MAIL ADDRESS:	
		STREET 1:		3 WEST MAIN STREET, SUITE 201
		CITY:			IRVINGTON
		STATE:			NY
		ZIP:			10533
</SEC-HEADER>
<DOCUMENT>
<TYPE>8-K
<SEQUENCE>1
<FILENAME>y16984e8vk.txt
<DESCRIPTION>8-K
<TEXT>
<PAGE>
================================================================================

                                  UNITED STATES
                       SECURITIES AND EXCHANGE COMMISSION
                             WASHINGTON, D.C. 20549


                                    FORM 8-K


                                 CURRENT REPORT
     PURSUANT TO SECTION 13 OR 15(D) OF THE SECURITIES EXCHANGE ACT OF 1934



Date of Report (Date of earliest event reported) JANUARY 25, 2006



                         ELECTRO-OPTICAL SCIENCES, INC.
             ------------------------------------------------------
             (Exact name of registrant as specified in its charter)


          DELAWARE                     333-125517                 13-3986004
- ----------------------------          ------------           -------------------
(State or other jurisdiction          (Commission               (IRS Employer
     of incorporation)                File Number)           Identification No.)


    3 WEST MAIN STREET, SUITE 201,
           IRVINGTON, NEW YORK                                          10533
- ----------------------------------------                             ----------
(Address of principal executive offices)                             (Zip Code)


Registrant's telephone number, including area code (914) 591-3783

         (Former name or former address, if changed since last report.)


Check the appropriate box below if the Form 8-K filing is intended to
simultaneously satisfy the filing obligation of the registrant under any of the
following provisions (see General Instructions A.2. below):


|_|    Written communications pursuant to Rule 425 under the Securities Act (17
       CFR 230.425)

|_|    Soliciting material pursuant to Rule 14a-12 under the Exchange Act (17
       CFR 240.14a-12)

|_|    Pre-commencement communications pursuant to Rule 14d-2(b) under the
       Exchange Act (17 CFR 240.14d-2(b))

|_|    Pre-commencement communications pursuant to Rule 13e-4(c) under the
       Exchange Act (17 CFR 240.13e-4(c))

================================================================================
<PAGE>

ITEM 1.01 - ENTRY INTO A MATERIAL DEFINITIVE AGREEMENT

     (a)  On January 25, 2006 the Registrant entered into a Production Agreement
          with Askion GmbH of Germany (the "Production Agreement") pursuant to
          which Askion was engaged to produce and test commercial-grade
          MelaFind(R) systems (the "Pivotal Trial Systems") to be used in the
          Registrant's pivotal trial. The pivotal trial will be used by the
          United States Food & Drug Administration as the basis for determining
          the safety and effectiveness of MelaFind(R). Pursuant to the
          Production Agreement, delivery of the Pivotal Trial Systems is
          contemplated to commence in January 2006 and be completed in April
          2006.

          MelaFind(R), a non-invasive point-of-care instrument to assist in the
          early diagnosis of melanoma, is the Registrant's flagship product.

          A copy of the Production Agreement is filed herewith as Exhibit 10.1.

ITEM 5.02 - APPOINTMENT OF CHIEF OPERATING OFFICER

     (c)  Gerald Wagner, Ph.D., a current director of the Registrant, has been
          appointed acting Chief Operating Officer, effective as of January 25,
          2006. Dr. Wagner, 62, became a member of the Registrant's board of
          directors in May 2005. Gerald Wagner Consulting LLC, a company owned
          and operated by Dr. Wagner, has provided consulting services to the
          Registrant since March 2005. Gerald Wagner Consulting LLC specializes
          in international project management, technology and application
          consulting and company assessments. From March 1992 until September
          2003, Dr. Wagner was a Senior Vice President, Lab Testing Systems, at
          Bayer, Inc.

ITEM 7.01 - REGULATION FD DISCLOSURE

         On January 30, 2006 the Registrant issued a press release announcing it
had entered into the Production Agreement. A copy of the press release is
furnished as Exhibit 99.1 to this report. Exhibit 99.1 is furnished to, but not
filed with, the Securities and Exchange Commission.

ITEM 9.01 - FINANCIAL STATEMENTS AND EXHIBITS

     (b)  Exhibits.


EXHIBIT
NUMBER                                DESCRIPTION
- -------          -----------------------------------------------------------

10.1             Production Agreement between the Registrant and Askion GmbH
                 dated as of January 25, 2006

99.1             Press Release of the Registrant dated January 30, 2006
<PAGE>

                                   SIGNATURES

         Pursuant to the requirements of the Securities Exchange Act of 1934,
the Registrant has duly caused this report to be signed on its behalf by the
undersigned hereunto duly authorized.


                                       Electro-Optical Sciences, Inc.


Date: January 31, 2006

                                       By: /s/ Joseph V. Gulfo
                                           -----------------------------------
                                           President & Chief Executive Officer
                                           (Principal Executive Officer)


                                        2
<PAGE>

                                  EXHIBIT INDEX


EXHIBIT NO.                            DESCRIPTION
- -----------      -----------------------------------------------------------

10.1             Production Agreement between the Registrant and Askion GmbH
                 dated as of January 25, 2006

99.1             Press Release of the Registrant dated January 30, 2006


                                        3
</TEXT>
</DOCUMENT>
<DOCUMENT>
<TYPE>EX-10.1
<SEQUENCE>2
<FILENAME>y16984exv10w1.txt
<DESCRIPTION>EX-10.1: PRODUCTION AGREEMENT
<TEXT>
<PAGE>

                                                                    EXHIBIT 10.1


                    PRODUCTION AGREEMENT FOR COMMERCIAL-GRADE
                         MELAFIND PIVOTAL TRIAL SYSTEMS


This Agreement, dated as of January 25, 2006, is between Askion GmbH., a German
Company with limited liability, with its registered office at Gewerbepark
Keplerstrasse, D-07549, Gera., Germany ("Askion") and Electro-Optical Sciences,
Inc., a Delaware Corporation with its office at One Bridge Street, Suite 15,
Irvington, New York 10533 USA ("EOS").

Askion and EOS are parties to a previous agreement, executed by Askion on
13/04/05 and by EOS on 18/05/05, as supplemented upon the parties' agreement to
the Askion Price Proposal. Thereafter, Askion and EOS prepared a draft of this
agreement, including certain Annexes. EOS later issued, and Askion accepted,
certain purchase orders adopting certain provisions of the Annexes. This
agreement executed on 13/04 and 18/05/2005 and these purchase orders are
referred to collectively as the "First Agreement." The First Agreement obligates
Askion to supply engineering design and production services to EOS relating to
the development of a number of Test Fixtures, based upon specifications supplied
by EOS, all as described therein, and the use of the Test Fixtures and other
Askion equipment to test EOS-developed working models of the EOS proposed
MelaFind product and its sub-assemblies. The First Agreement also obligates
Askion, with support by EOS, to provide services and supplies to develop and
produce at least four "Design Prototypes" for delivery to EOS. Finally, the
First Agreement obligates the parties jointly to develop an agreed-upon set of
specifications for prototypes that are capable of being utilized in a pivotal
clinical trial for the purpose of proving the safety and effectiveness of
MelaFind, an optical probe for the precise, multi-spectral imaging of suspicious
lesions, the analysis of those lesions, and the automatic determination of
whether or not the lesions represent melanoma, under the procedures mandated by
the US FDA ("Pivotal Trial Systems").

Askion and EOS are also parties to a Letter of Intent, executed by Askion on
19/05/05 and by EOS on 31/05/05. The Letter of Intent recognized the need to
develop a price for the sale by Askion and purchase by EOS of commercial-grade
systems that will be used in the pivotal clinical trial for PMA approval of
MelaFind ("Pivotal Trial Systems") as soon as sufficient progress was achieved
in the development of final specifications and the production and testing of
Design Prototypes. This Agreement will replace the Letter of Intent with respect
to the Design Prototypes. The parties continue to express their mutual intent to
collaborate in the design and production of commercial MelaFind units. This
design will be based upon the Pivotal Trial Systems, modified as appropriate in
light of the experience of EOS with the Pivotal Trial Systems in the pivotal
clinical trial, and on the final ruling of the US FDA on the EOS pending
application for PreMarket Approval of MelaFind.

THEREFORE, the parties to this agreement agree as follows:

      1. SPECIFICATIONS. The specifications for the Pivotal Trial Systems are
set out in Annex 1 attached hereto (the "Specifications"). EOS shall be entitled
to modify

[ * ] = CONFIDENTIAL TREATMENT REQUESTED. THE OMITTED MATERIAL HAS BEEN FILED
        SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION.

                                       1
<PAGE>
                                                                    EXHIBIT 10.1

the Specifications and to request corresponding modifications to the
Askion design, under two conditions: (a) if testing of the Design Prototypes
demonstrates that revision is required to correct defects, and (b) at the
request of EOS but not because of the discovery of a defect. In the latter case,
Askion shall only be required to implement the design modification if it is
feasible. EOS shall be responsible for the extra cost of any such changes. Any
request for a change shall be implemented by submission of a written change
order request and a written response.

      2. PROCUREMENT. The complete Bill of Materials for each Pivotal Trial
System is as set out in Annex 2-A. EOS shall be responsible for the acquisition
and supply to Askion of those parts and sub-assemblies specified in Annex 2-B.
Askion shall be responsible for the procurement of those parts and
sub-assemblies specified in Annex 2-C.

      3. PRICE. EOS shall pay Askion the price set forth in Annex 3 in return
for the delivery, on the delivery dates set out below, of 40 separate Pivotal
Trial Systems. If EOS should request Askion to assemble and deliver more than 40
Pivotal Trial Systems, the price for each additional Pivotal Trial System shall
be negotiated based on the cost of the first 40 units, but taking into account
Askion's learning curve on the first 40 units.

      4. DELIVERY DATES. Askion will produce the first five Pivotal Trial
Systems during January, 2006. EOS and Askion will together test those five units
extensively during February, 2006. Askion will produce at least eight additional
Pivotal Trial Systems in February, 2006; at least twelve in March, 2006 (for a
total of at least 20), and fifteen in April, 2006, or whatever number is
required to reach a total of 40. Each of the 35 Pivotal Trial Systems
constructed after January, 2006 will undergo testing in the month after
production. The dates of final delivery to EOS of each of the 40 Pivotal Trial
Systems will depend on the test results. Assuming a favorable outcome, each
Pivotal Trial System will be delivered shortly after the completion of testing.
If testing identifies defects requiring correction, the parties will work
together to establish a schedule for repair of the affected unit, and will
jointly assess the impact of the test result on other units. If EOS should
request Askion to assemble and deliver more than 40 Pivotal Trial Systems, the
parties shall agree upon the schedule for procurement, assembly, testing, and
delivery for the extra units.

      5. QUALITY ASSURANCE. Askion shall utilize record-keeping, inventory, and
other policies and procedures that allow EOS to comply with US FDA and
comparable European standards for the design, development, and production of
medical devices, as well as with CE, ISO 9000, UL, and similar standards. Annex
4 sets out a description of such policies and procedures. Askion has consented
to the use of its name as the provider of Pivotal Trial Systems in connection
with any filings required to be made with the US Food and Drug Administration or
other United States agencies or other authoritative entities in order to procure
necessary permits, consents, approvals, and the like. Askion represents that it
anticipates receiving ISO 9000 certification in the first quarter of 2006 and
that the Pivotal Trial Systems will be manufactured in compliance with
applicable ISO 9000 standards.


[ * ] = CONFIDENTIAL TREATMENT REQUESTED. THE OMITTED MATERIAL HAS BEEN FILED
        SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION.


                                       2
<PAGE>
                                                                    EXHIBIT 10.1

      6. INTELLECTUAL PROPERTY.

a) The final development and manufacture of the Pivotal Trial Systems according
to the Specifications is a work for hire, and any inventions inherent in that
work shall belong to EOS, provided that EOS shall reimburse Askion for any
obligations Askion may incur as a result under the German inventorship laws. Any
invention made jointly by employees of EOS and Askion shall be jointly owned.
EOS will receive a paid-up, exclusive, world-wide license, with rights to
sub-license in connection with the use of the Pivotal Trial Systems and with the
use of the technology in subsequent versions of the MelaFind product. EOS also
receives the right to utilize any Askion technology embedded in the Pivotal
Trial Systems, together with the right to develop literature describing the
product and its use. Askion will retain all of its other pre-existing
intellectual property rights, with no implied license to EOS. The parties shall
keep the terms of this agreement confidential.

   (b) Except to the extent expressly authorized by this Agreement or otherwise
agreed in writing, the parties agree that, for the term of this Agreement and
for ten (10) years thereafter, the receiving party shall keep confidential and
shall not publish or otherwise disclose to a third party or use for any purpose
other than as provided for in this Agreement any information (including, without
limitation, any clinical test data) and materials furnished to it by the other
party pursuant to this Agreement (collectively, "Confidential Information"),
except to the extent that it can be established by the receiving party by
competent proof that such Confidential Information:

          (i)  was already known to the receiving party, other than under an
obligation of confidentiality, at the time of disclosure by the other party;

          (ii)  was generally available to the public or otherwise part of
the public domain at the time of its disclosure to the receiving party;

          (iii) became generally available to the public or otherwise part of
the public domain after its disclosure and other than through any act or
omission of the receiving party in breach of this Agreement; or

          (iv) was disclosed to the receiving party, other than under an
obligation of confidentiality, by a third party who had no obligation to the
disclosing party not to disclose such information to others.

   (c) Each party may disclose the other's Confidential Information and the
existence and terms of this Agreement to the extent such disclosure is
reasonably necessary in filing or prosecuting patent applications, prosecuting
or defending litigation, complying with applicable governmental regulations
(including, without limitation, regulations promulgated by the U.S. Securities
and Exchange Commission) or conducting pre-clinical or clinical trials, provided
that if a party is required by law or regulation to make any such disclosure of
the other party's Confidential Information it will give reasonable

[ * ] = CONFIDENTIAL TREATMENT REQUESTED. THE OMITTED MATERIAL HAS BEEN FILED
        SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION.


                                       3
<PAGE>
                                                                    EXHIBIT 10.1

advance notice to the other party of such disclosure requirement and, except to
the extent inappropriate in the case of patent applications, will use its best
efforts to secure confidential treatment of such information required to be
disclosed.

   (d) Sections 6(b), (c) and (d) hereof shall survive the termination or
expiration of this Agreement for a period of ten (10) years.

   (e) Annex 5 sets out the procedures that will be utilized for identification
of each document created or modified by Askion pursuant to this Agreement in
order to ensure that EOS retains final ownership of such documents, while Askion
may still integrate these documents in its own quality control system. At least
one version of each such document must have all of its text in the English
language. Askion shall keep complete, accurate and authentic accounts, notes,
data and records of work performed under this Agreement, including, without
limitation, records pertaining to the methods and facilities used by it for the
manufacture, processing, testing, packing, labeling, holding and distribution of
Pivotal Trial Systems in accordance with the applicable regulations in the
United States [and other countries] so that the Pivotal Trial Systems may be
used in human therapies.

      7. LIMITATION OF LIABILITY. Askion shall not be responsible for the proper
operation of the MelaFind device. Askion shall not be responsible for the
failure of any Pivotal Trial Systems to achieve its intended purpose so long as
it has met its delivery Specifications. If a Pivotal Trial System should fail to
meet its Specifications, the limit of Askion's liability shall be to correct the
defects.

      8. RELATIONSHIP BETWEEN CONTRACTS. This contract does not supersede the
First Agreement. This contract shall become binding only upon its execution by
Askion and EOS. This Agreement, with its Annexes, comprises the entire agreement
between the parties on the subject of sale and purchase of Pivotal Trial
Systems, and supersedes all prior negotiations, including the Letter of Intent.
No change to these terms shall be binding unless made in writing and signed by
authorized representatives of both parties.

      9. In the case of any disagreement that cannot be resolved by a joint
technical review committee, the dispute shall be submitted to mandatory
arbitration before a panel of three arbitrators convened in Paris, France
pursuant to the provisions of the International Chamber of Commerce. Each party
shall choose one arbitrator, and the two thus chosen shall select the third, who
shall be the chairperson. Judgment on any resulting arbitration award may be
sought and entered in any court of jurisdiction. This Agreement shall be
governed and construed in accordance with the law of the State of New York
applicable to contracts made and to be performed entirely within the State of
New York.

[ * ] = CONFIDENTIAL TREATMENT REQUESTED. THE OMITTED MATERIAL HAS BEEN FILED
        SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION.


                                       4
<PAGE>
                                                                    EXHIBIT 10.1


   ELECTRO-OPTICAL SCIENCES, INC.          ASKION, GMBH.

   /s/ Joseph V. Gulfo                     /s/ Lutz Doms
   ---------------------                   ------------------------------

   Joseph V. Gulfo,                        Lutz Doms,

   President & Chief Executive Officer     Managing Director



[ * ] = CONFIDENTIAL TREATMENT REQUESTED. THE OMITTED MATERIAL HAS BEEN FILED
        SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION.


                                       5
<PAGE>
                                                                    EXHIBIT 10.1

                        ANNEXES FOR PIVOTAL TRIAL SYSTEMS

ANNEX 1: SPECIFICATION

The current version of the MelaFind Specification, developed by EOS, is
incorporated by reference as Attachment 1. At such time as EOS has developed a
final version of the Specification for the Pivotal Trial Systems, the parties
shall agree upon an appropriate amendment to this Agreement or its annexes to
account for any changes affecting the cost of any item or the manufacturability
of the MelaFind unit.

ANNEX 2-A:  BILL OF MATERIALS

The current version of the Bill of Materials, developed by Askion with
assistance from EOS, is incorporated by reference as Attachment 2. It is in the
form of an Excel spreadsheet, with several tabs. The Bill of Materials includes
prices, but these are for Design Prototypes. These prices may be different for
Pivotal Trial Systems. At such time as the parties have agreed upon a final
version of the Bill of Materials, the parties shall agree upon an appropriate
amendment to this Agreement to reflect any change in the cost of any item or in
the manufacturability of the MelaFind unit.

ANNEX 2-B: EOS SUPPLY TO ASKION

The Bill of Materials, Attachment 2, includes a tab identifying those parts and
subassemblies that EOS shall acquire and supply to Askion.

 ANNEX 2-C: ASKION PROCUREMENT

The Bill of Materials, Attachment 2, includes a tab identifying those parts and
subassemblies that as to which Askion shall be responsible for the procurement.

ANNEX 3:  PRICING

Until the parties have agreed upon a per-unit transfer price for the 40 Pivotal
Trial Systems, Askion shall be paid its actual cost of manufacture in accordance
with the estimate given by Askion. The cost of manufacture equals the following:

      -     Price for raw material purchased by Askion including a [ * ] %
            handling factor for vendor selection, purchasing, testing,
            warehousing etc., plus

Actual direct and indirect labor costs, and overhead (utilities, fuel, and the
like but without fixtures) for assembly of 40 units, estimated at Euro [ * ],
not to exceed Euro [ * ], plus actual costs of testing. The testing is to be in
compliance with the EOS Test Plan. The parties have informally agreed upon
certain elements of a test plan, but have not completed this task. Once the Test
Plan has been agreed upon, a copy shall be attached as an Exhibit to this Annex,
and the cost of testing shall be specified. At present, it is estimated that the
direct and indirect labor costs, and overhead (utilities, fuel, and the like but
without fixtures) for assembly, testing and delivery of 40 Pivotal Trial Systems
will aggregate Euro [ * ], and will not exceed Euro [ * ].

[ * ] = CONFIDENTIAL TREATMENT REQUESTED. THE OMITTED MATERIAL HAS BEEN FILED
        SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION.


                                       6
<PAGE>
                                                                    EXHIBIT 10.1


ANNEX 4:  APPLICABLE REGULATORY STANDARDS

The Pivotal Trial Systems shall be designed to be capable of satisfying US FDA
standards applicable to Medical Devices. To the extent possible, the Pivotal
Trial Systems shall be designed in a way that will minimize the amount of
subsequent modifications required for subsequent MelaFind units to achieve
compliance with European medical device, environmental, and recycling standards.
All recordkeeping and other quality standards applicable to either US or
European medical device manufacturing shall be enforced.

ANNEX 5:  DOCUMENT PRESERVATION

Reference is made to the Askion MelaFind Project File. This file contains
substantially all documents received, altered, or created that relate to the
design, the specifications, or the process of assembling MelaFind units,
including elements of the Device History File (DHF), the Device History Record,
(DHR), and the Device Master Record (DMR). Askion will transmit the current
contents of this file regularly to EOS for storage in the memory of the EOS
server using the established computer link. EOS will advise Askion regarding the
location on its server where the copy will reside.



[ * ] = CONFIDENTIAL TREATMENT REQUESTED. THE OMITTED MATERIAL HAS BEEN FILED
        SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION.


                                       7
<PAGE>
                                                                    EXHIBIT 10.1



                                  ATTACHMENT 1

                             MELAFIND SPECIFICATIONS





                                      [ * ]



[ * ] = CONFIDENTIAL TREATMENT REQUESTED. THE OMITTED MATERIAL HAS BEEN FILED
        SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION. THE MATERIAL
        OMITTED FROM THIS ATTACHMENT CONSISTS OF 38 PAGES.




                                       8
<PAGE>
                                                                    EXHIBIT 10.1




                                  ATTACHMENT 2

                                BILL OF MATERIALS





                                      [ * ]









[ * ] = CONFIDENTIAL TREATMENT REQUESTED. THE OMITTED MATERIAL HAS BEEN FILED
        SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION. THE MATERIAL
        OMITTED FROM THIS ATTACHMENT CONSISTS OF 2 PAGES.



                                       9





</TEXT>
</DOCUMENT>
<DOCUMENT>
<TYPE>EX-99.1
<SEQUENCE>3
<FILENAME>y16984exv99w1.txt
<DESCRIPTION>EX-99.1: PRESS RELEASE
<TEXT>
<PAGE>
                                                                    Exhibit 99.1



ELECTRO-OPTICAL SCIENCES, INC. SIGNS PRODUCTION AGREEMENT WITH ASKION GMBH TO
PRODUCE MELAFIND(R) IMAGING DEVICE

IRVINGTON, N.Y., Jan 30, 2006 /PRNewswire-FirstCall via COMTEX News Network/ --
Electro-Optical Sciences, Inc. (EOS) (Nasdaq: MELA), a medical device company
focused on designing and developing a non-invasive, point-of-care instrument to
assist in the early diagnosis of melanoma, today announced that it has entered
into an agreement with ASKION GmbH for the production of the MelaFind(R)
hand-held imaging device.

The agreement calls for ASKION to produce MelaFind imaging devices for EOS to be
utilized in the company's pivotal trial. EOS anticipates conducting the trial at
over 20 clinical study sites in the U.S. The purpose of the pivotal trial is to
establish the safety and efficacy of MelaFind in the imaging of suspicious skin
lesions. Financial terms of the agreement were not disclosed.

"This agreement is an important milestone for EOS and is a significant step in
our pre-commercialization process," said Joseph V. Gulfo, President and CEO of
EOS. "2006 will be an exciting year for EOS as we conduct our clinical trials
and anticipate PMA approval and commercialization of MelaFind in 2007."

"ASKION has a solid reputation for top quality production and manufacturing. I
have had first-hand dealings with ASKION management and personnel for 15 years
since my days at Bayer Diagnostics US and AGFA. We look forward to working with
them to produce these commercial grade units," said Gerald Wagner, PhD, Acting
Chief Operating Officer and member of EOS's Board of Directors.

"We are pleased that EOS has selected ASKION to produce the MelaFind imaging
system. We look forward to supporting the company in their strategy of
developing a leading technology in the detection of melanoma," said Lutz Doms,
Managing Director of ASKION GmbH.

About Electro-Optical Sciences, Inc.

EOS is a medical device company focused on designing and developing a
non-invasive, point-of-care instrument to assist in the early diagnosis of
melanoma. MelaFind, EOS's flagship product, features a hand-held imaging device
that emits multiple wavelengths of light to capture images of suspicious
pigmented skin lesions and extract data. The data are then analyzed against
EOS's proprietary database of melanomas and benign lesions using sophisticated
algorithms in order to provide information to the physician and produce a
recommendation of whether the lesion should be biopsied.

Melanoma is the deadliest of skin cancers, responsible for approximately 80% of
all skin cancer deaths. Unless melanoma is detected early and excised with
proper margins, the patient survival rate is poor, as there is currently no cure
for advanced stage melanoma.

For more information on EOS, visit http://www.eosciences.com.

About ASKION GmbH

The company started as a part of Agfa-Gevaert AG in 1991, mostly with employees
from the former Carl Zeiss Jena. Its focus originally was on development and
production of printing machines for the photo industry. In 1995 it expanded
these activities to digital printing devices using color laser exposure systems.

ASKION GmbH was formed in 2005 as a management buy-out. Located in the center of
the Jena-Dresden-Leipzig industrial and technology region, the company's
facilities include 77,000 square ft R&D and manufacturing areas, which have
cleanrooms, and climate- and light-testing equipment. ASKION draws upon many
years of experience in the development of complex systems, including electronic
hard- and software, opto-electronics and test equipment as well as strict
adherence to quality management standards. Production capabilities encompass:
samples, prototypes, initial ramp-up and commercial production or transfer of
serial production to other locations. Specific applications include printing and
exposure as well as medical devices and instrumentation. For more information on
ASKION visit http://www.Askion.com
<PAGE>
Safe Harbor

This press release includes "forward-looking statements" within the meaning of
the Securities Litigation Reform Act of 1995. These statements include but are
not limited to our plans, objectives, expectations and intentions and other
statements that contain words such as "expects," "contemplates," "anticipates,"
"plans," "intends," "believes" and variations of such words or similar
expressions that predict or indicate future events or trends, or that do not
relate to historical matters. These statements are based on our current beliefs
or expectations and are inherently subject to significant uncertainties and
changes in circumstances, many of which are beyond our control. There can be no
assurance that our beliefs or expectations will be achieved. Actual results may
differ materially from our beliefs or expectations due to economic, business,
competitive, market and regulatory factors.

SOURCE Electro-Optical Sciences, Inc.

Fern Lazar of Lazar Partners for Electro-Optical Sciences, Inc.,
+1-212-867-1762, flazar@lazarpartners.com
</TEXT>
</DOCUMENT>
</SEC-DOCUMENT>
-----END PRIVACY-ENHANCED MESSAGE-----
